Back to News & Insights
Product Insights

Wheeled humanoid teleoperation platform | Which trainable fields can be retained: time, observations, actions, platform identifier

Trainable samples must align at least four things: time, observation, action, and body identifier. The wheeled humanoid teleoperation body provides the body and part of the action carrier. The vision system is listed as stereo depth / RGB optional. Wide-angle camera 130° FOV × 3, located at chest / back / chassis. The laser…

2026-10-03
TOBI
Product Insights
Wheeled humanoid teleoperation platform | Which trainable fields can be retained: time, observations, actions, platform identifier
Product InsightsWheeled humanoid teleoperation robot2026-10-03

A trainable sample must align at least four things: time, observation, action, and body identifier. The wheeled humanoid teleoperation body provides the body and part of the action carrier. The vision system is listed as binocular depth / RGB optional. Wide-angle cameras: 130° FOV × 3, located at the chest / back / chassis. LiDAR is a single-line laser with detection range greater than 40 m (reflectivity 90%). The voice interaction module is a ring of 6 microphones, optional. Depth-camera versions: data-acquisition version Orbbec 335LG; standard version Intel RealSense D405; optional Intel RealSense D435. Which sensor stream the observation comes from is governed by this sentence. Video without timestamps is just a recording.

Data Recording

Action fields are modeled separately from degrees of freedom, chassis, and end-effector. Total active degrees of freedom: 21, split as dual arms 14, waist 3, legs 2, neck 2. Movement speed: 0.1–1.5 m/s. Turning radius 690 mm, defined as in-place rotation. The end-effector can be fitted with a multi-DOF dexterous hand or gripper depending on the task. The page states compatibility with grippers and dexterous hands from AOK, BrainCo, Zhixing, and others, as well as the RX75, RM75, and RM65 robotic arm platforms. Compatibility is not a standard-configuration list. Do not write any quantity not present in these three sentences into the data dictionary as already collected. If gripper open/close uses the RMG22-65, the open/close is the 2-second definition from the gripper page, not one dimension of the platform's degrees of freedom, unless the recording scheme explicitly encodes it as one dimension and clearly states the unit.

A human's head-mounted device and gloves can operate in parallel, but cannot be labeled with the motion labels of this machine body. Cross-embodiment transfer is a research topic, not a feature already completed on this page. Works such as Open X-Embodiment require the embodiment to be explicitly labeled, which precisely shows that sensors from different pages cannot be merged into one robot.

Quality statement: the action space of this sample equals the written configuration for this order, not the union of all options on the wheeled humanoid teleoperation body product page. If an option was not purchased, it is not in the sample.

Wheeled humanoid teleoperation robot
Figure 1 | Wheeled humanoid teleoperation platform. The caption only states that this is a device photo from the product page; the appearance is not interpreted as parameters not present in the table.

How to Use This Page in This Version

The data dictionary starts with four columns: time, observation, action, body. The body column records the wheeled humanoid teleoperation body and this order's configuration sheet number; do not write "teleoperation platform." The number of observation streams comes from: the vision system is listed as binocular depth / RGB optional. Wide-angle cameras: 130° FOV × 3, located at the chest / back / chassis. LiDAR is a single-line laser with detection range greater than 40 m (reflectivity 90%). The voice interaction module is a ring of 6 microphones, optional. Depth-camera versions: data-acquisition version Orbbec 335LG; standard version Intel RealSense D405; optional Intel RealSense D435. The joints in the action column come from: total active degrees of freedom 21, broken down as both arms 14, waist 3, legs 2, neck 2. The chassis comes from: movement speed 0.1–1.5 m/s. Turning radius 690 mm, specified as in-place turning. The end effector comes from: a multi-degree-of-freedom dexterous hand or gripper can be added to the end effector depending on the task. The page states compatibility with grippers and dexterous hands from Aoyi, Qiangnao, Zhixing, and others, as well as the RX75, RM75, and RM65 robotic-arm platforms. Compatibility is not a standard-configuration list. For anything in the four columns that is not on the page, the dictionary writes "not collected," not a default value.

File naming should include date, robot unit, and configuration sheet number. Do not use non-traceable terms like "final version" or "new data." If the end effector or kit column changes on the same day, the configuration sheet number must change; otherwise, samples from two different action spaces will end up in the same folder.

Human-side devices go in a separate directory. Head-mounted video, glove posture, and robot joint data must not be merged into a single training file when they are not aligned. Merging is a subsequent step, contingent on the synchronization scheme having been specified. This page does not promise merging as a factory function.

The quality note written for humans restates the boundaries: an optional camera that was not purchased does not appear in the observation column; a recommended gripper that was not specified does not appear in the action column; the success rate in the paper is not a label for this batch of data. /product-body-humanoid.html is the basis for the platform column.

Line-by-Line Verification

Degrees of freedom. Total active degrees of freedom: 21, broken down as dual arms 14, waist 3, legs 2, neck 2. This row only states the number of joints and body parts that have been publicly disclosed. It does not evaluate intelligence, and it does not automatically include the waist, legs, neck, or whole-machine total that are not explicitly named on the page. When writing the action vector, only create channels for body parts listed in this row; body parts not listed remain blank. Do not write blanks as 0, because 0 would be treated by the training script as a real angle. Do not fill in the degrees-of-freedom integer from another device to complete this row. If the master-slave joint order is not given on the page, mark it as pending written configuration confirmation; do not number it yourself. The joint set in the action column equals this row — no more, no less. The action vector only creates channels for body parts named in this row; unnamed body parts are left blank, not filled with 0.

Payload and mass. Single-arm payload 5 kg. Overall weight approximately 125 kg, which is not the single-arm payload. The numbers in this row must be read aloud with their subject: rated, self-weight, total mass, envelope, friction, or gripping force. If the subjects differ, they cannot be merged into one number, nor can conversions not given on the page be performed. If an object in the field is heavier, that does not retroactively change the specification; a larger specification does not prove that every grasping method reaches that limit. Tool mass is undetermined; do not write the arm's rated payload as the graspable object mass. The acceptance sheet retains the original units. If a mass label uses "rated," it must state that it is the specification limit, not the object weight of every sample. During acceptance, read the subject first and then the number; if the subjects differ, split into two rows.

Dimensions and scale. Overall dimensions 570 × 465 × 1680 mm. Chassis width and shoulder width are kept within 465 mm. This row describes exterior or structural dimensions, used to check doorways, elevators, tabletops, or transport; it is not an operating height and not a reach. Do not add it to the vertical range. If a diagram shows protrusions, antennas, or a person's standing position not present in this row, note separately that they are not part of the specification. If weight appears in an adjacent row, do not write it into the dimension sentence. The exterior does not enter the action vector. Doorways, elevators, and transport are checked against the exterior only; do not treat this row as an operating height.

Operating range. Vertical reach 2100 mm. Horizontal reach 1818 mm, excluding the end effector. This row describes the range the hand or lift can reach; the definition must follow the original sentence: vertical working range, reach, motion radius, or stroke — these cannot be added together or renamed. If "excluding the end effector" is written, it must remain in the figure caption. If the original text does not specify units, retain the note "units not specified"; do not delete it for tidiness. The working range may be written into task metadata, not into joint angles. The figure caption retains the range definition from the original sentence, as well as the words "excluding end effector" and "units not specified."

Motion. Movement speed 0.1–1.5 m/s. Turning radius 690 mm, specified as in-place turning. This row describes how the ground base or main arm moves. Four-wheel steering, four-wheel drive, differential drive, in-place turning radius, and rotational speed are terms for different mechanisms and cannot be substituted for one another. The published speed is a capability, not a recommended teaching speed; teaching may be slower, but a slower speed is recorded under experimental conditions and is not written back as a specification. If the page does not state slope climbing or positioning, do not borrow from another page. Whether a chassis channel exists is determined by whether this row describes movement. Teaching speed may be lower, but the lower value is recorded under operating conditions and does not change the published capability in this row.

Power. Battery 40 Ah (BMS). Charging time approximately 2 hours. "Approximately 2 hours" refers to charging, not runtime; the page does not specify runtime in hours. This row retains only the electrical terms that appear on the page: voltage, capacity, runtime, charging, current, or power. If there is no hours value, write "runtime not specified"; do not fill the blank with hours from a neighboring page. Do not rename charging time as runtime. Rated and maximum values must be listed in separate columns. Preserve "approximately" for approximate values. Do not sum the amp-hours of multiple devices and present the total as one device's battery. The battery row does not produce sensor timestamps. Hours, charging, or current values that do not appear are left as "not specified" and are not copied in from a neighboring page.

Perception and computing. The vision system is listed as binocular depth / RGB optional. Wide-angle cameras: 130° FOV × 3, located at the chest / back / chassis. LiDAR is a single-line laser with detection range greater than 40 m (reflectivity 90%). The voice interaction module is a ring of 6 microphones, optional. Depth-camera versions: data-acquisition version Orbbec 335LG; standard version Intel RealSense D405; optional Intel RealSense D435. This row inventories the items explicitly stated in perception, computing, or communications, and preserves the terms standard, standard configuration, optional, and optional configuration. Unchecked optional items do not count. If the cover conflicts with the list, cite the list while not pretending the cover sentence does not exist. Head-mounted devices and gloves do not enter this row. Processors, storage capacity, or camera stream counts that are not written out must not be drawn into the system diagram. The topics in the observation column must match the stream count in this row. Optional sensors that were not purchased do not enter this order's data dictionary.

End effector. A multi-DOF dexterous hand or gripper can be added to the end effector depending on the task. The page states compatibility with grippers and dexterous hands from AYI, BrainCo, Zhixing, and others, as well as the RX75, RM75, and RM65 robotic arm platforms. Compatibility is not a standard configuration list. This line refers to where contact or grasping occurs. Quick-change, compatible, and recommended are not models already included in the box. The ring fixture on the main arm is not an end-effector gripper. Force, stroke, and payload figures remain as listed in their respective rows and are not merged into a single system-level metric just because they are mounted on one platform. Flange and protocol mappings that have not been provided are marked as to be confirmed, not as plug-and-play. End-effector states only enter the action column once the model is determined. "Supports" or "compatible" without a specific model cannot be treated as delivered.

Boundary. The upper body and wheeled chassis are a modular structure. How the split modules connect to other chassis must be confirmed per the project interface; do not write them as already connected in the public table. This line is a boundary deliberately separated on the page: another model, another column, another product page, or an interface that still requires project confirmation after modularization. The boundary is not a defect note; it prevents verbally buying two pages as one. When writing a proposal, copy the boundary into "Not included in this scope." If equipment not included is added later, open a new configuration sheet; do not go back and change the body name in old samples. Equipment not included must not appear in the body identifier. Equipment within the boundary must be ordered separately; do not rename old samples to say it is already included.

Configuration column. The voice module and depth camera version both have optional rows. Options are not written into the deliverables when unchecked. The end-effector brand must be named in the configuration sheet; do not write "compatible means already included." This line distinguishes standard, recommended, and optional. Recommended and optional items are not delivered if unchecked. When the standard row conflicts with the parameter table row, keep both rows and use "Locked for this order" to indicate which one is actually delivered, rather than striking out one row in the order without signing off. Price and lead time are not written into this line's restatement. The sample's configuration sheet number must be able to explain whether the recommended item is checked. Unchecked recommended and optional items are written as not delivered on the order.

Quotable. The following can be copied into an appendix: 21 (14+3+2+2); 570×465×1680 mm; approximately 125 kg; 465 mm width limit; vertical reach 2100 mm; horizontal reach 1818 mm (excluding end-effector); in-place turning radius 690 mm; 0.1–1.5 m/s; single arm 5 kg; 40 Ah; charging approximately 2 hours. This line is the type that can be pasted into an appendix: it has a subject, has units, and can be traced back to the original sentence on the product page. When pasting, preserve "approximately," "excluding," "not specified," "optional," and "recommended." Do not convert and keep only the result. If the same number has different meanings on two pages, write it as two lines in the appendix. Do not mix test protocols into specification excerpts. The data sheet cites the appendix's original sentences; do not write a separate set of numbers. When pasting into the appendix, paste the words "approximately," "excluding," and "optional" along with the numbers.

Do not write. Do not write charging approximately 2 hours as battery life 2 hours. Do not write the folding model's 20 DoF or approximately 6 hours onto this unit. Do not write the lifting model's 900 mm as this unit's lifting stroke. This line is a negative statement for review. It does not describe what the equipment can do; it only prevents hours, degrees of freedom, load subjects, or cover slogans from neighboring pages from being written in. If a negative statement is hit, revert to the product page's original sentence; do not interpret it as "close enough." Do not write in success rates from external papers or total hours not published on this site. If a number from a negative statement appears in the dictionary, judge it as mixed writing. If manuscript retrieval hits a negative statement, revert to the product page's original sentence.

ProjectsPublic-Facing Positioning of This Page
Degrees of FreedomTotal active degrees of freedom: 21, broken down as dual arms 14, waist 3, legs 2, neck 2.
Load and MassSingle-arm payload 5 kg. Total unit weight is approximately 125 kg, which is not the single-arm payload.
Form Factor and ScaleOverall dimensions 570 × 465 × 1680 mm. The chassis width and shoulder width are kept within 465 mm.
Operating RangeVertical reach 2100 mm. Horizontal reach 1818 mm, excluding the end effector.
MotionMotion speed 0.1–1.5 m/s. Turning radius 690 mm; the specification refers to in-place rotation.
PowerBattery 40 Ah (BMS). Charging time approximately 2 hours. The approximately 2 hours refers to charging, not runtime; the page does not state runtime in hours.
Perception & ComputeThe vision system is listed as binocular depth / RGB optional. Wide-angle camera 130° FOV ×3, located on the chest / back / chassis. The LiDAR is a single-line laser with detection range greater than 40 m (90% reflectivity). The voice interaction module is a ring-shaped 6-microphone array, optional. Depth camera versions: data collection version Orbbec 335LG; standard version Intel RealSense D405; optional Intel RealSense D435.
End EffectorA multi-degree-of-freedom dexterous hand or gripper can be added to the end effector depending on the task. The page explicitly states compatibility with grippers and dexterous hands from Aoyi, Qiangnao, Zhixing, and others, as well as the RX75, RM75, and RM65 robotic arm platforms. Compatibility is not a standard configuration list.
BoundaryThe upper body and wheeled chassis are modular. How to connect to other chassis after separation must be confirmed per the project interface; do not state in the public table that it is already connected.
Configuration PanelBoth the voice module and depth camera versions have optional rows. Optional items are not included in unchecked deliveries. The end-effector brand must be specified by name in the configuration sheet; do not write "compatible means already included."
ExcerptableAttachment copy: 21 (14+3+2+2); 570×465×1680 mm; approximately 125 kg; 465 mm maximum width; vertical reach 2100 mm; horizontal reach 1818 mm (excluding end-effector); in-place rotation radius 690 mm; 0.1–1.5 m/s; single arm 5 kg; 40 Ah; approximately 2 hours of charging.
Do not writeDo not write "approximately 2 hours of charging" as "2 hours of battery life." Do not attribute the folding model's 20 DoF or approximately 6 hours of battery life to this unit. Do not write the lifting model's 900 mm as this unit's lifting stroke.
Another image from the wheeled humanoid teleoperation platform image library
Figure 2 | Another image from the product page gallery. The page does not label this image as front view or side view, so no view name is added here.

Relationship to Public Methods and Adjacent Pages

The embodiment is an actuator, not a dataset. Running the machine once does not automatically produce trainable action labels. A trainable demonstration must at least be alignable on: time, observation (which camera stream, resolution, frame rate), action (which of the joints, gripper, chassis), and the identifier of that specific physical unit. If any one is missing, the file is merely a log, not an imitation learning sample.

A person wearing E6 or E2 walking around produces the human's head pose and hand data, not the motion of a robot end effector. The public documentation for E2 does not include on-board SLAM; poses are reconstructed offline. A 4 Hz preview is not training footage. E6 training should read the 60 Hz raw stream, not the 10 Hz preview. The G7 and G2-L gloves record the hand, not the joints of this rig. These devices can be used simultaneously, but the files serve different roles.

The "success rate" in strategy papers is computed on the authors' own tasks and data. Writing ALOHA or Diffusion Policy results as "achievable with this embodiment" mistakes method literature for an acceptance report.

This article lists: the fields that must appear on the recording sheet if this embodiment is used for demonstration, and which adjacent products' data cannot impersonate its motions.

Before handing off to a colleague

During data dictionary review, ask four questions for each column: where does the time come from, how many observation streams are there, what action channels exist, and which configuration sheet does the rig belong to. If any column's answer is "approximately," the dictionary is returned. Human-side directories and rig directories are stored separately. When the configuration sheet number changes, new samples must not be written into the old directory. The last sentence of the quality note is repeated: optional items not purchased are not in the samples, and the paper's success rate is not a label. The dictionary version is submitted together with the product page verification date. In directory permissions, unsynchronized and signed-configuration data are placed under two separate root directories. The training account has read-only access to signed configurations by default. The root directory name for human-side data contains "human"; the rig directory name contains the rig and configuration sheet number. Directories without numbering are cleaned up weekly and not transferred into the training set. The required fields in the quality note template are: time, number of observation streams, action channels, and rig number — the form cannot be saved if these are left blank. The save button does not offer "fill in later."

First, if the four columns cannot be answered, return the dictionary.

Second, the human side and the robot side get separate root directories.

Third, whenever the configuration number changes, switch directories.

Fourth, directories without numbering do not enter the training set.

Fifth, required fields cannot be left blank when saving.

Sixth, a paper's success rate is not a label.

Continue Reading

Back to Product Center View this product page

This article was written on October 3, 2026, for selection and specification verification purposes. Device parameters are subject to the product page tables and do not constitute a supply commitment. External papers only illustrate how problems are framed in the industry; their success rates and data scales belong to the original authors' experiments and are not TOBI's measured results. Phone: +86 137 5502 0164.